With the photovoltaic power station, especially the rooftop distributed photovoltaic power generation has been widely popularized. While photovoltaic power generation benefits the people, there are often reports of fire accidents or even accidental personal injury and major property losses due to photovoltaic power plants. Today, let's discuss the fire safety issues that should be paid attention to during the operation and maintenance of photovoltaic power plants.
The DC side of photovoltaic power generation has high voltage and large current. There are many string connectors, and the installation environment is complicated. Many connectors are exposed to sunlight or exposed to wind and rain, which are prone to poor contact and even fire, burning and other fire hazards. Electrical fires are very dangerous, and once they happen, the losses will be heavy. Therefore, the principle of "prevention first" must be implemented to prevent electrical fires before they occur.
Loji kuasa fotovoltaik terutamanya menghalang kebakaran litar, termasuk:
· The DC side connector sparks the arc and causes a fire;
· Fire caused by equipment failure (combiner box, inverter, distribution box, transformer, high and low voltage switchgear, etc.);
· Lightning strikes cause fire, etc.
Jika kebakaran ditemui di kemudahan kuasa stesen janakuasa fotovoltaik, penyongsang hendaklah dimatikan serta-merta, bekalan kuasa AC hendaklah diputuskan, dan kemudian litar rentetan fotovoltan hendaklah diputuskan secepat mungkin untuk dipotong sepenuhnya dari sumber arka rentetan fotovoltaik, untuk memastikan keselamatan kakitangan pemadam kebakaran dan mengawal kebakaran di peringkat kemudian. .
Dalam keadaan kritikal, untuk mendapatkan inisiatif memadam kebakaran dan mendapatkan masa untuk mengawal kebakaran, anda boleh memadamkan api dengan elektrik dengan syarat memastikan keselamatan diri, dan kemudian memutuskan bekalan kuasa pada tempat yang sesuai. masa, tetapi anda mesti memberi perhatian kepada keselamatan.
Sekiranya berlaku kebakaran di stesen janakuasa fotovoltaik, bomba harus dimaklumkan dan diingatkan secepat mungkin bahawa peralatan fotovoltaik di atas bumbung dialirkan elektrik, dan bomba harus memakai kasut penebat. Jangan sentuh badan atau alat pemadam api di tangan anda dengan wayar hidup atau peralatan elektrik untuk mengelakkan kejutan elektrik semasa memadam kebakaran.
Loji kuasa fotovoltaik hendaklah dilengkapi dengan peralatan pemadam kebakaran-yang mencukupi, termasuk alat pemadam api serbuk kering, karbon dioksida, 1211, alat pemadam api karbon tetraklorida atau pasir kering. Alat pemadam api air dan buih adalah dilarang sama sekali untuk kebakaran elektrik.
Untuk penyongsang, pengawal dan litar instrumen ketepatan lain atau peralatan elektrik seperti motor yang menjejak kurungan, secara amnya tidak sesuai menggunakan serbuk kering, pasir, dll. untuk memadamkan api. Alat pemadam api karbon dioksida, 1211, dan karbon tetraklorida harus digunakan untuk memadamkan api. Untuk mengelakkan serpihan daripada jatuh ke dalam peralatan menyebabkan kerugian yang lebih besar.
Pada masa yang sama, perlu juga mengekalkan jarak tertentu apabila menggunakan peralatan untuk memadamkan api:
(1) Bagi badan dengan voltan 10 kV dan ke bawah, jarak minimum antara muncung dan badan bercas hendaklah tidak kurang daripada 0.4 m, dan bagi mereka yang mempunyai voltan 35 kV dan ke atas, ia tidak boleh kurang daripada 0.6 m;
(2) Apabila kerosakan tanah berlaku pada-peralatan elektrik voltan tinggi atau talian stesen janakuasa fotovoltaik, kakitangan penyelamat dalaman tidak boleh masuk dalam jarak 4 m dari titik kerosakan; anggota penyelamat luar tidak boleh mendekati dalam jarak 8 m dari titik kerosakan. Apabila memasuki julat di atas, mereka mesti memakai kasut penebat (tahan tahap Voltan melebihi 10KV), memakai sarung tangan penebat apabila menyentuh cangkerang dan bingkai peralatan.